Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 570
Filtrar
1.
São Paulo med. j ; 142(3): e2023121, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1530517

RESUMO

ABSTRACT BACKGROUND: The High Activity Arthroplasty Score (HAAS) is a self-administered questionnaire, developed in British English, that reliably and validly measures the levels of sports activities in patients following hip and knee arthroplasty surgery. OBJECTIVE: To cross-culturally adapt the HAAS to Brazilian Portuguese language. DESIGN AND SETTING: A cross-sectional study was conducted at a public university hospital in Brazil. METHODS: The Brazilian version of the HAAS was created through a six-step process: translation, synthesis, committee review, pretesting, back-translation, and submission to developers. The translation step was conducted by two independent bilingual translators, both native speakers of Brazilian Portuguese. The back-translation was performed by an independent translator, a native speaker of British English. To ensure the questionnaire's comprehensibility, 46 volunteers (51% men; average age 34-63) participated in the pre-testing step. RESULTS: The cross-cultural adaptation process necessitated modifications to certain terms and expressions to achieve cultural equivalence with the original HAAS. CONCLUSION: The HAAS has been translated from English into Brazilian Portuguese and culturally adapted for Brazil. The validation process for HAAS-Brazil is currently underway.

2.
Rev. bras. ortop ; 58(5): 781-789, Sept.-Oct. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1529949

RESUMO

Abstract Objective The present study aimed to compare the cure rate recovery time and Merle d'Aubigné-Postel functional (MAPF) score after single-stage surgery (C1T) or two-stage surgery (C2T) to treat prosthetic infections of the hip considering sociodemographic and clinical features of the patients. Materials and Methods The present retrospective study occurred in a single center from 2011 to 2014 with 37 studied cases including 26 treated with C1T and 11 with C2T. We compared the cure rate recovery time and MAPF score in the two groups as well as the sociodemographic and clinical features of the patients. We also considered surgical complications and the most common infectious agents. Results The C1T group had a faster functional recovery than the C2T group but there were no significant differences in the cure rate surgical complications or MAPF score. However C1T group patients were significantly younger which may have influenced the outcomes. Staphylococcus spp. was the most common infectious agent (62%). Conclusion Although C2T appears superior regarding infection cure C1T may be preferable for faster functional recovery. However it is critical to consider individual patient characteristics when choosing treatment. Further research with a larger sample size is required to confirm these results.


Resumo Objetivo Comparar a taxa de cura, o tempo de recuperação e a pontuação na escala funcional de Merle d'Aubigné-Postel (EFMA) entre a cirurgia em tempo único (C1T) e a cirurgia em dois tempos (C2T) no tratamento de infecções protéticas do quadril, considerando as características sociodemográficas e clínicas dos pacientes. Materiais e Métodos Foi realizado um estudo retrospectivo num único centro, entre 2011 e 2014, com um total de 37 casos estudados, sendo 26 tratados com C1T e 11 com C2T. Foram comparadas a taxa de cura, o tempo de recuperação e a pontuação EFMA entre os dois grupos, bem como as características sociodemográficas e clínicas dos pacientes. Foram também consideradas as complicações cirúrgicas e o agente infeccioso mais comum. Resultados O grupo C1T teve uma recuperação funcional mais rápida do que o grupo C2T, mas não houve diferenças significativas na taxa de cura, nas complicações cirúrgicas ou na pontuação EFMA. No entanto, o grupo C1T era significativamente mais jovem, o que pode ter influenciado os resultados. Staphylococcus spp. foi o agente infeccioso mais comum (62%). Conclusão Embora a C2T pareça ser superior em termos de cura de infecção, a C1T pode ser preferível para uma recuperação funcional mais rápida. No entanto, as características individuais dos pacientes devem ser consideradas na escolha do tratamento. São necessárias mais pesquisas com um tamanho de amostra maior para confirmar estes resultados.


Assuntos
Humanos , Reoperação , Artroplastia de Quadril , Prótese de Quadril , Infecções
3.
Rev. bras. ortop ; 58(5): 818-821, Sept.-Oct. 2023. graf
Artigo em Inglês | LILACS | ID: biblio-1529941

RESUMO

Abstract It is not common to encounter arteriovenous malformations (AVMs) during total hip arthroplasty (THA). We report the present case to draw attention to the possibility of an AVM during the direct anterior approach (DAA) for THA, which, if not borne in mind, may lead to the myriad of complications related to excessive bleeding. An 81-year-old female presented to the emergency department with a left femoral neck fracture. She elected to undergo a THA via the DAA. Abnormal appearing blood vessels were present near the ascending circumflex branches, which provided difficulty in achieving hemostasis. Excessive blood loss was noted, and the patient received one unit of packed red blood cells during the operation. Hemoglobin and hematocrit dropped in the days following surgery, requiring several additional transfusions of blood products. When the patient complained of progressive left leg swelling on postoperative day 3, a computed tomography revealed large hematomas within the left adductors and the left iliopsoas muscle. Active extravasation was identified arising from a branch of the left profunda femoral artery, as well as an arteriovenous fistula (AVF) in this area. Bleeding was controlled by selective endovascular coil embolization. As of current knowledge, this is the first reported intraoperative discovery of congenital arteriovenous malformation (AVM) with subsequent development of postoperative arteriovenous fistula and associated symptomatic hematomas in the setting of THA using the DAA. Early recognition and intervention of vascular malformations is essential in preventing potential limb- or life-threatening surgical complication.


Resumo Não é comum encontrar malformações arteriovenosas (MAV) durante a artroplastia total do quadril (ATQ). Relatamos o presente caso para chamar a atenção para a possibilidade de uma MAV durante a abordagem anterior direta (AAD) para ATQ, que se não for considerada, pode levar a uma miríade de complicações relacionadas ao sangramento excessivo. Uma mulher de 81 anos foi apresentada ao pronto-socorro com fratura no pescoço do fêmur esquerdo. Ela optou por se submeter a uma artroplastia total do quadril (ATQ) através da AAD. Vasos sanguíneos aparentemente anormais estavam presentes perto dos ramos circunflexos ascendentes, proporcionando dificuldade em alcançar hemostasia. A perda excessiva de sangue foi notada e a paciente recebeu uma unidade de glóbulos vermelhos embalados durante a operação. Hemoglobina e hematócrito caíram nos dias seguintes à cirurgia, exigindo várias transfusões adicionais de produtos sanguíneos. Quando a paciente reclamou de inchaço progressivo na perna esquerda no terceiro dia pós-operatório, a tomografia computadorizada revelou hematomas grandes dentro dos adutores esquerdos e do músculo iliopsoas esquerdo. A extravasão ativa foi identificada a partir de um ramo da artéria femoral esquerda, bem como de uma fístula arteriovenosa (FAV) nesta área. O sangramento foi controlado por embolização seletiva da bobina endovascular. A partir do conhecimento atual, esta é a primeira descoberta intraoperatória relatada de MAC congênita com desenvolvimento subsequente de FAV pós-operatória e hematomas sintomáticos associados no cenário de ATQ utilizando a AAD. O reconhecimento precoce e a intervenção de malformações vasculares são essenciais para prevenir possíveis complicações cirúrgicas de membros ou de risco de vida.


Assuntos
Humanos , Feminino , Idoso de 80 Anos ou mais , Malformações Arteriovenosas , Artroplastia de Quadril
4.
Rev. bras. ortop ; 58(3): 514-522, May-June 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1449822

RESUMO

Abstract Objective To analyze the profile and perception ofpatients on the waiting list for total hip arthroplasty (THA) about performing elective surgeries during the COVID-19 pandemic. Methods From July to November 2021, patients on the THA waiting list were interviewed during outpatient consultations. To compare the groups regarding categorical variables, the Chi-square test or Fisher's exact test was applied, and for quantitative variables the Mann-Whitney test was applied. The results were calculated using the Statistica program version 7. Results 39 patients answered the questionnaire. The mean age was 58.95 years, with 53.85% male. Approximately 60% expressed concern about contracting or transmitting COVID-19 to their family members after hospitalization for THA. 58.9% of patients felt hampered by the delay in scheduling elective surgeries during the pandemic. 23% lost or had a family member who lost their job during the pandemic, with a statistical difference for the group under 60 years old (p = 0.04). Conclusion Most patients were concerned about becoming infected and exposing family members to COVID-19 after surgery and noted damage due to suspensions and delay in scheduling elective surgeries. The economic impact of the pandemic was revealed by the rate of 23% of respondents who lost or had a family member who lost their job during the pandemic, being higher in patients under 60 years of age (p = 0.04).


Resumo Objetivo Analisar o perfil e a percepção dos pacientes em lista de espera para artroplastia total do quadril (ATQ) sobre a realização das cirurgias eletivas durante a pandemia pela COVID-19. Métodos De julho a novembro de 2021, foram entrevistados pacientes em lista de espera para ATQ durante consultas ambulatoriais. Para comparar os grupos com relação às variáveis categóricas foi aplicado o Teste Qui-quadrado ou Teste exato de Fisher e para as variáveis quantitativas foi aplicado o teste de Mann-Whitney. Os resultados foram calculados utilizando o programa Statistica versão 7. Resultados 39 pacientes responderam ao questionário. A média de idade foi de 58,95 anos, sendo 53,85% do sexo masculino. Aproximadamente, 60% manifestaram preocupação em contrair ou transmitir COVID-19 aos seus familiares após internação hospitalar para ATQ. 58,9% dos pacientes sentiram-se prejudicados pelo atraso no agendamento das cirurgias eletivas durante a pandemia. 23% perderam ou tiveram algum familiar que perdeu o emprego durante a pandemia, havendo diferença estatística para o grupo com menos de 60 anos (p = 0,04). Conclusão A maioria dos pacientes sentiram preocupação em infectar-se e expor familiares à COVID-19 após a cirurgia e notaram prejuízo pelas suspensões e atraso no agendamento de cirurgias eletivas. O impacto econômico da pandemia revelou-se pela taxa de 23% de entrevistados que perderam ou tiveram algum familiar que perdeu seu emprego durante a pandemia, sendo maior nos pacientes menores de 60 anos (p = 0,04).


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Aceitação pelo Paciente de Cuidados de Saúde , Procedimentos Cirúrgicos Eletivos , Artroplastia de Quadril , COVID-19
5.
Rev. bras. ortop ; 58(3): 500-506, May-June 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449819

RESUMO

Abstract Objectives Although osteonecrosis of the femoral head is a prevalent condition, its effects on gait parameters have not been thoroughly studied and are not well-established in the current literature. The primary aim of the present study is to describe gait in patients with a diagnosis of osteonecrosis. Methods This is a cross-sectional study. Nine patients diagnosed with osteonecrosis of the femoral head who were regularly followed-up at an outpatient clinic were selected for the present study and underwent gait analysis using Vicon Motion Capture Systems. Spatiotemporal data was obtained, and joint angles were calculated using an Euler angle coordinate system. Distal coordinate systems were used to calculate joint momentsand forceplatestoobtaingroundreactionforces. Results Patients with osteonecrosis presented with slower velocity (0.54 m/s ± 0.19) and smaller cadence (83.01 steps/min ± 13.23) than healthy patients. The pelvic obliquity range of motion was of 10.12° ± 3.03 and rotation was of 18.23° ± 9.17. The mean hip flexion was of 9.48° ± 3.40. Ground reaction forces showed reduced braking and propelling forces. Joint moments were reduced for flexion and adduction (0.42 Nm/kg ± 0.2 and 0.30 Nm/kg ± 0.11, respectively) but the abduction moment was increased (0.42 Nm/kg ± 0.18). Conclusions The present study showed that osteonecrosis of the femoral head presents compensatory gait mechanisms, with increased pelvic motion and decreased knee flexion to protect the hip joint. Decreased moments for hip flexion and adduction were also identified and muscle weakness for those groups may be correlated to the disease.


Resumo Objetivos Embora a osteonecrose da cabeça do fêmur seja uma lesão prevalente, seus efeitos sobre os parâmetros da marcha não foram minuciosamente estudados e não estão bem estabelecidos na literatura atual. O objetivo principal do presente estudo é descrever a marcha em pacientes com osteonecrose. Métodos Trata-se de um estudo transversal. Nove pacientes com diagnóstico de osteonecrose da cabeça do fêmur, sob acompanhamento regular em ambulatório, foram selecionados para o presente estudo e submetidos à análise da marcha com Vicon Motion Capture Systems. Os dados espaciais e temporais foram obtidos e os ângulos articulares foram calculados com o sistema de coordenadas angulares de Euler. Sistemas de coordenadas distais e plataformas de força foram utilizados para o cálculo de momentos articulares e de forças de reação ao solo, respectivamente. Resultados Os pacientes com osteonecrose apresentaram menor velocidade (0,54 m/s ± 0,19) e menor cadência (83,01 passos/minuto ± 13,23) do que pacientes saudáveis. As amplitudes de movimento de obliquidade e rotação pélvica foram de 10,12°± 3,03 e 18,23° ± 9,17, respectivamente. A média de flexão do quadril foi de 9,48° ± 3,40. O estudo das forças de reação ao solo revelou redução das forças de frenagem e propulsão. Os momentos articulares de flexão e adução caíram (0,42 Nm/kg ± 0,2 e 0,30 Nm/kg ± 0,11), mas o momento de abdução aumentou (0,42 Nm/kg ± 0,18). Conclusões O presente estudo mostrou que a osteonecrose da cabeça do fêmur é associada a mecanismos compensatórios da marcha, com aumento da movimentação pélvica e diminuição da flexão do joelho para proteção da articulação do quadril. A redução dos momentos de flexão e adução do quadril também foi identificada e a fraqueza destes grupos musculares pode estar correlacionada à doença.


Assuntos
Humanos , Fenômenos Biomecânicos , Artroplastia de Quadril , Necrose da Cabeça do Fêmur , Análise da Marcha
6.
Rev. bras. ortop ; 58(3): 523-531, May-June 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449816

RESUMO

Abstract Objective To evaluate the clinical and radiographic results and survival of the acetabular revision surgery of total hip arthroplasty with cemented implant without the use of reinforcement ring, associated with structural homologous bone grafting. Methods A total of 40 patients (44 hips) operated from 1995 to 2015 were retrospectively analyzed. Radiographs were evaluated according to the classification of the acetabular bone defect, graft shape, and the presence of osseointegration. Cases were considered as failures when the migration of the implant was > 5 mm in any direction, and/or the progression of radiolucency lines around the acetabular component were > 2 mm. We verified the association of radiographic findings with cases of failure using statistical tests and analyzed survival using the Kaplan-Meier curve. Results Of the 44 hips, 45.5% of the acetabular defects were Paprosky type 3A and 50% were 3B. In 65% of the hips, the graft configuration was classified as Prieto type 1 and in 31% as type 2. No radiographic evidence of osseointegration was observed in 13.6% of the cases. We observed 9 (20.5%) reconstruction failures. A correlation was observed between reconstruction failure and the absence of radiographic signs of graft osseointegration. Conclusion We observed good clinic and radiographic results, with survival of 79.54% in a mean follow-up of 9.65 years. Also, there was an association between absence of radiographic signs of osseointegration of the structural graft and failure in this series of patients with large bone defects. The failures did not correlate with the severity of the acetabular bone defect, thickness, or graft configuration.


Resumo Objetivo Avaliarosresultadosclínicos, radiográficos e a sobrevida da cirurgia de revisão acetabular de artroplastia total de quadril com implante cimentado sem uso de anel de reforço, associado à enxertia óssea homóloga estrutural. Métodos Um total de 40 pacientes (44 quadris) operados de 1995 a 2015 foram analisados retrospectivamente. As radiografias foram avaliadas de acordo com a classificação do defeito ósseo acetabular, o formato do enxerto e à presença de osteointegração. Foram considerados casos de insucesso a migração do implante > 5 mm em qualquer direção e/ou a progressão de linhas de radioluscência em torno do componente acetabular > 2mm. Verificamos a associação dos achados radiográficos com os casos de falha utilizando testes estatísticos e analisamos a sobrevida utilizando a curva de Kaplan-Meier. Resultados Dos 44 quadris, 45,5% dos defeitos acetabulares eram Paprosky tipo 3A e 50%, 3B. Em 65% dos quadris, a configuração do enxerto foi classificada como tipo 1 de Prieto e em 31% como tipo 2. Não foi observada evidência radiográfica de osteointe-gração em 13,6% dos casos. Observamos 9 (20,5%) falhas de reconstrução. Foi observada correlação entre falha da reconstrução com a ausência de sinais radiográficos de osteointegração do enxerto. Conclusão Observamos bons resultados clínicos e radiográficos, com sobrevida de 79,54% em seguimento médio de 9,65 anos. Também houve associação entre ausência de sinais radiográficos de osteointegração do enxerto estrutural e falha nesta série de pacientes com grandes defeitos ósseos. As falhas não se correlacionaram com a severidade do defeito ósseo acetabular, espessura ou configuraçãodoenxerto.


Assuntos
Humanos , Reoperação , Transplante Homólogo , Estudos Transversais , Osseointegração , Transplante Ósseo , Artroplastia de Quadril
7.
Rev. bras. ortop ; 58(2): 246-251, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449800

RESUMO

Abstract Objective The present study aims to assess the reproducibility of digital planning for cementless total hip arthroplasty (THA) among surgeons with different levels of experience. In addition, it attempts to determine the degree of planning reliability based on a contralateral THA or on a spherical marker positioned at the greater trochanter for calibration. Methods Two evaluators with different experience levels (A1 and A2) performed independently the retrospective digital surgical planning of 64 cementless THAs. Next, we compared the planning with the implants used in the surgery. The reproducibility was excellent when planning and implants were identical; proper in case of a single-unit variation; and inappropriate if there was variation in two or more units. The present analysis also determined the calibration accuracy between the contralateral THA and the spherical marker at the greater trochanter level. Results The present study demonstrated greater success when the most experienced evaluator performed the planning and greater accuracy for the contralateral THA. When splitting the analysis per parameter (contralateral THA or spherical marker), there was a statistical difference only for the planning of A1 and the implants used in the surgery. This difference occurred in the excellent category, with 67.3% for contralateral THA compared with 30.6% for a spherical marker (p < 0.001), and in the inappropriate category, with 7.1% for contralateral THA compared with 30.6% for a spherical marker (p < 0.001). Conclusions Digital planning is more accurate when performed by an experienced evaluator. The contralateral prosthesis head was a better reference than a marker on the greater trochanter.


Resumo Objetivo Avaliar a reprodutibilidade do planejamento digital da artroplastia total de quadril (ATQ) sem cimento entre cirurgiões com diferentes níveis de experiência e o grau de confiabilidade no planejamento baseado na ATQ contralateral com o método de marcador esférico posicionado ao nível do trocanter maior. Método Dois avaliadores com níveis de experiência diferentes (A1 e A2) realizaram de forma independente o planejamento digital operatório retrospectivo de 64 ATQs sem cimento. O planejamento foi comparado com os implantes utilizados na cirurgia, sendo classificados como: excelentes, quando idênticos; adequados, quando houve variação de uma unidade; e inadequados, quando ocorreu variação de duas ou mais unidades. Na presente análise, também foi avaliada a acurácia do parâmetro de calibragem entre a ATQ contralateral comparada com o marcador esférico ao nível do trocanter maior. Resultados O estudo demonstrou maior êxito no planejamento quando realizado pelo avaliador mais experiente, com maior acurácia na ATQ contralateral. Ao fragmentar a análise de acordo com o parâmetro utilizado (ATQ contralateral ou marcador esférico), houve diferença estatística apenas na comparação do planejamento do avaliador A1 com os implantes utilizados na cirurgia. Esta diferença ocorreu na classificação excelente com 67,3% em ATQ contralateral como parâmetro contra 30,6% com marcador esférico (p < 0,001) e inadequado de 7,1% contra 30,6%, respectivamente (p < 0,001). Conclusões A acurácia do planejamento digital é mais precisa quando realizada por um avaliador experiente e a utilização da cabeça de prótese contralateral como referência se mostrou superior à utilização de um marcador no trocanter maior.


Assuntos
Humanos , Planejamento de Assistência ao Paciente , Radiografia , Artroplastia de Quadril
8.
Rev. bras. ortop ; 58(2): 240-245, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449799

RESUMO

Abstract Objective Tranexamic acid (TXA) is an antifibrinolytic that is widely used for decreasing blood loss and blood transfusion rates in total hip arthroplasty. However, there is limited evidence of topical TXA usage in hip hemiarthroplasty for femoral neck fractures. The present study aimed to evaluate the effects of topical TXA on blood loss and on blood transfusions in femoral neck fracture patients who underwent cemented bipolar hemiarthroplasty. Methods Twenty-six patients with femoral neck fractures who were scheduled for bipolar cemented arthroplasty were randomized into two groups. The first group of 12 patients received topical TXA during their operation, whereas 14 patients in the second group received a placebo. Hematocrit was measured at 6 and 24 hours postoperatively. Blood transfusions and postoperative complications were also recorded. Results Total blood loss was not different between the TXA group and the control group (TXA group: 459.48 ± 456.32 ml, and control group: 732.98 ± 474.02 ml; p = 0.14). However, there were no patients within the TXA group who required a blood transfusion, while there were 4 patients in the control group who received allogenic blood transfusions (p = 0.044). There were no postoperative complications, such as wound complication, venous thromboembolism, or cardiovascular complications within either group. Conclusion Topical TXA could not decrease total blood loss but was able to reduce transfusion rates in patients who underwent cemented bipolar hip hemiarthroplasty in femoral neck fractures. Further studies in doses of topical TXA in a larger sample size would be beneficial. Level of Evidence II.


Resumo Objetivo O ácido tranexâmico (TXA) é um antifibrinolítico amplamente utilizado para diminuir as taxas de perda de sangue e de transfusão de sangue na artroplastia total do quadril. No entanto, há evidências limitadas de uso tópico de TXA na hemiartroplastia do quadril para fraturas no pescoço femoral. O presente estudo teve como objetivo avaliar os efeitos do TXA tópico na perda de sangue e transfusões de sangue em pacientes com fratura femoral que foram submetidos a hemiartroplastia bipolar cimentada. Métodos Vinte e seis pacientes com fraturas no pescoço femoral e programados para artroplastia cimentada bipolar foram randomizados em dois grupos. O primeiro grupo de 12 pacientes recebeu TXA tópico durante a operação; no segundo grupo, 14 pacientes receberam placebo. O hematócrito foi medido às 6 e 24 horas no pósoperatório. Também foram registradas transfusões de sangue e complicações pósoperatórias. Resultados A perda total de sangue não foi diferente entre o grupo TXA e o grupo controle (grupo TXA: 459,48 ±456,32 ml; e grupo controle: 732,98 ±474,02 ml; p = 0,14). No entanto, não houve pacientes dentro do grupo TXA que necessitaram de transfusão de sangue, enquanto 4 pacientes no grupo controle fizeram transfusões de sangue halogênicas (p = 0,044). Não houve complicações pós-operatórias, tais como complicação da ferida, tromboembolismo venoso ou complicações cardiovasculares dentro de qualquer grupo. Conclusão O TXA tópico não conseguiu diminuir a perda total de sangue, mas foi capaz de reduzir as taxas de transfusão, em pacientes submetidos a hemiartroplastia de quadril bipolar cimentada em fraturas no pescoço femoral. Outros estudos com doses de TXA tópico em um tamanho amostral maior seriam benéficos. Nível de Evidência II.


Assuntos
Humanos , Ácido Tranexâmico/uso terapêutico , Artroplastia de Quadril , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia
9.
Rev. bras. ortop ; 58(2): 252-256, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449793

RESUMO

Abstract Objective The present study aims to evaluate the effectiveness of the periarticular hip infiltration technique in the postoperative period of total hip arthroplasty. Methods This is a randomized double-blind controlled clinical trial in patients with femoral neck fractures or hip osteoarthritis submitted to a total hip arthroplasty at our institution. The periarticular infiltration technique consisted of the administration of an anesthetic (levobupivacaine) and a steroid (dexamethasone) agent in the nociceptor-rich tissues of the hip after orthopedic implants placement. The control group received an injection of 0.9% saline into the same tissues. Pain, range of motion, and use of opioid analgesic agents after 24 and 48hours of the procedure were evaluated, as well as the presence of adverse effects, time to resume walking, and total hospitalization time. Results The study evaluated 34 patients. The experimental group required fewer opioid agents between 24 and 48 hours. The reduction in pain scores was greater in the placebo group. Conclusion Periarticular anesthetic infiltration as a method of postoperative analgesia for total hip arthroplasty reduced the rates of opioid intake between 24 and 48hours. It provided no benefits regarding pain, mobility, length of stay, or complications.


Resumo Objetivo Este estudo tem como objetivo avaliar a eficácia da técnica de infiltração periarticular do quadril no pós-operatório de artroplastia total do quadril. Métodos Estudo clínico randomizado duplo-cego controlado. O estudo foi realizado nos pacientes com fratura de colo femoral ou osteoartrose de quadril, submetidos ao procedimento cirúrgico de artroplastia total do quadril em nossa instituição. A técnica de infiltração periarticular consistiu na aplicação da combinação de um anestésico (levobupivacaína) com um corticosteroide (dexametasona) nos tecidos ricos em nociceptores do quadril, após a colocação dos implantes ortopédicos. No grupo controle, foi realizada infiltração de soro fisiológico 0,9% nos mesmos tecidos. Após 24 e 48 horas do procedimento, foram avaliados os quesitos de dor, amplitude de movimentos, uso de analgésicos opióides, presença de efeitos adversos, período do início da deambulação e o tempo total de hospitalização. Resultados Trinta e quatro pacientes foram estatisticamente avaliados no estudo. Foi observada uma redução no consumo de opioides entre 24 e 48 h no grupo experimental. Uma redução maior da pontuação de dor foi observada no grupo placebo. Conclusão A infiltração periarticular anestésica como método de analgesia pós-operatória de artroplastia total do quadril, neste estudo, reduziu as taxas deconsumo de opioides


Assuntos
Humanos , Masculino , Feminino , Reabilitação , Artroplastia de Quadril , Analgesia , Injeções Intra-Articulares
10.
Rev. bras. ortop ; 58(1): 133-140, Jan.-Feb. 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1441351

RESUMO

Abstract Objective The aim of the present study was to determine the influence of resident involvement on acute complication rates in revision total hip arthroplasty (THA). Methods Using the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database, 1,743 revision THAs were identified from 2008 to 2012; 949 of them involved a resident physician. Demographic information including gender and race, comorbidities including lung disease, heart disease and diabetes, operative time, length of stay, and acute postoperative complications within 30 days were analyzed. Results Resident involvement was not associated with a significant increase in the risk of acute complications. Total operative time demonstrated a statistically significant association with the involvement of a resident (161.35 minutes with resident present, 135.07 minutes without resident; p< 0.001). There was no evidence that resident involvement was associated with a longer hospital stay (5.61 days with resident present, 5.22 days without resident; p= 0.46). Conclusion Involvement of an orthopedic resident during revision THA does not appear to increase short-term postoperative complication rates, despite a significant increase in operative times.


Resumo Objetivo O objetivo do presente estudo foi determinar a influência do envolvimento dos residentes nas taxas de complicações agudas na revisão da artroplastia total do quadril (ATQ). Métodos Utilizando o banco de dados do American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP, na sigla em inglês), foram identificadas 1.743 revisões de ATQs entre 2008 e 2012; 949 delas envolveram um médico residente. Foram analisadas informações demográficas, incluindo gênero e raça, comorbidades, incluindo doenças pulmonares, doenças cardíacas e diabetes, tempo de permanência e complicações agudas pós-operatórias no prazo de 30 dias. Resultados O envolvimento dos residentes não foi associado a um aumento significativo no risco de complicações agudas. O tempo de operação total demonstrou associação estatisticamente significativa com o envolvimento de um residente (161,35 minutos com residente presente, 135,07 minutos sem residente; p< 0,001). Não houve evidência de que o envolvimento do residente tenha sido associado a um maior tempo de internação hospitalar (5,61 dias com residente presente, 5,22 dias sem residente; p= 0,46). Conclusão O envolvimento de um residente ortopédico durante a revisão da ATQ não parece aumentar as taxas de complicações pós-operatórias de curto prazo, apesar de um aumento significativo nos tempos operacionais.


Assuntos
Humanos , Complicações Pós-Operatórias , Procedimentos Ortopédicos , Artroplastia de Quadril , Internato e Residência
11.
Chinese Journal of Orthopaedics ; (12): 223-229, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993432

RESUMO

Objective:To evaluate the efficacy and safety of non-osteotomy total hip arthroplasty (THA) in the treatment of Crowe IV developmental dysplasia of the hip (DDH).Methods:From Jan 2013 to Sep 2021, 46 patients (46 hips) in our department who underwent total hip arthroplasty without osteotomy for unilateral Crowe IV DDH were retrospectively analyzed, including 6 males and 40 females, with an average age of 41.2±7.2 years (25-61 years). The reduction of the femoral head was achieved successfully through moderate upward-posterior displacement of the movement center, gradual osteotomy of the calcar femorale, proper sinking of the femoral prosthesis and sufficient soft tissue release. The evaluation indexes included the basic condition of the operation (operation time, blood loss, blood transfusion, volume), clinical evaluation (Harris score of hip joint function, patient satisfaction, Trendelenburg sign), imaging evaluation (measurement of limb length and pelvic inclination) and incidence of complications.Results:The mean follow-up time was 72.2±8.8 months (8-101 months). The operation time was 97.2±12 min (84-112 min). The average intraoperative bleeding volume was 550±60 ml (350-850 ml). No patient had periprosthetic infection or fracture, no periprosthetic osteolysis or prosthesis loosening, and no patient needed revision surgery at the last follow-up of all cases. The average HHS score of patients increased from 42.5±12.3 points before surgery to 89.2±10.8 points at the last follow-up, and the difference was statistically significant ( t=19.35, P<0.001). Patient self-rated satisfaction: none was very dissatisfied, 1 patient were less satisfied (2%, 1/46), 4 patients were average (9%, 4/46), 19 patients were relatively satisfied (41%, 19/46), and 22 patients were very satisfied (48%, 22/46). The Trendelenburg sign of 46 cases was positive before operation, and all were negative at the last follow-up. The patients' true leg length discrepancy (LLD) measurement was -2.5±0.6 mm before surgery and 11.5±3.2 mm at the last follow-up ( t=29.17, P<0.05). Patients' perceived LLD was 28.2±5.1 mm before surgery and 3.4±1.4 mm at the last follow-up ( t=32.18, P<0.05). The length of the residual calcar femorale was 3.2±0.4 mm after THA. The limb extended distance of affected limb was 45.2±4.6 mm. The preoperative iliolumbar angle was -6.5°±2.3°, which returned to -0.5°±1.3° at the last follow-up ( F=651.97, P<0.05). Conclusion:For patients with unilateral type IV DDH, non-osteotomy THA is a safe and effective surgical method with simple operation and few complications. It can quickly correct pelvic tilt and lumbar compensatory scoliosis postoperatively.

12.
Chinese Journal of Orthopaedics ; (12): 155-163, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993423

RESUMO

Objective:To investigate the combination of internal fixation for periprosthetic fractures of the proximal femur (PFFF) after hip arthroplasty.Methods:The data of 58 patients with periprosthetic fractures after hip arthroplasty from May 2008 to March 2022 were retrospectively analyzed, including 31 males and 27 females. The average age was 75.5±18.2 years (range, 35-95 years). There were 39 total hip arthroplasty and 19 hemiarthroplasty; 37 biological prosthesis and 21 cemented prosthesis. Intraoperative periprosthetic fractures occurred in 6 cases and 52 cases postoperatively. Unified classification system (UCS): UCS IV.3A1 type 2 cases, 3A2 type 1 case, 3B1.1 type 19 cases, 3B2.1 type 25 cases, 3B3 type 2 cases, 3C type 9 cases. Fracture site: 3 cases in zone A (greater trochanter), 46 cases in zone B (around the femoral stem), and 9 cases in zone C (distal to the tip of the femoral stem. Internal fixation is composed of primary and secondary fixation, the main fixation method was the cerclage of steel wire or titanium cable, locking compression plate, and locking attachment plate fixation. The secondary fixation method was the cerclage of titanium cable, which was required to cover three zones A, B and C to form an overall balanced fixation. The modified Harris hip scores (mHHS), plate length, working length and screw number of different internal fixation combinations were compared.Results:The follow-up time was 54.2±21.6 months (range, 11-86 months). All patients showed signs of fracture healing at 10.2±1.5 weeks (range, 7-13 weeks) after operation, and bony union was observed at 19.6±1.3 weeks (range, 17-22 weeks) after operation. No delayed union or nonunion was observed. After operation, one case had a stress fracture and was revised with double-plate internal fixation; one case had a failed internal fixation and was revised with double-plate internal fixation and a large allograft bone graft. The mHHS score of UCSIV.3B2.1 group (80.3±4.6) was the lowest at 6 months after operation, and the difference between the groups of different types was statistically significant ( F=256.72, P<0.001). The score of simple internal fixation group (91.6±4.2) was higher than that of revision combined with internal fixation group (81.9±4.1), and the difference was statistically significant ( t=8.32, P<0.001). The plate length and working length were 24.9±2.5 cm and 12.6±1.7 cm for UCS IV.3B1.1, 25.4±2.6 cm and 13.6±1.8 cm for 3B2.1 and 28.1±2.5 cm and 4.9±1.9 cm for 3C, respectively ( F=5.33, P=0.005; F=6.78, P<0.001). The number of screws in zone A was significant difference among different UCS types ( F=52.67, P<0.001); UCS IV.3B1.1 (6.5±2.3) and 3B2.1 (6.7±2.2) were more than 3B3 (3.5±1.5) and 3C (3.7±1.6). The number of screws in zone B was significant difference among different UCS types ( F=42.15, P<0.001); The number of UCS IV.3B1.1 (2.3±1.6) and 3B2.1 (2.8±1.9) were significantly more than that of 3B3 (1.0±0.5) and 3C (1.2±0.6). The number of screws in zone C was significant differences among different UCS types ( F=39.62, P<0.001); The number of UCS IV.3B1.1 (3.8±1.9) and 3B2.1 (3.9±1.7) were more than that of 3B3 (2.0±0.5), the difference was statistically significant ( P<0.05). Conclusion:The function of hip after simple internal fixation of proximal femoral periprosthetic fractures was better than that of those who underwent revision at the same time; the number of screws of UCSIV.B1 and B2 is more than that of B3.

13.
Chinese Journal of Orthopaedics ; (12): 149-154, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993422

RESUMO

Objective:To investigate the safety and efficacy of a combined anterior and posterior approach in total hip arthroplasty (THA) for fused/ankylosed hip.Methods:37 patients who underwent THA for fused/ankylosed hip from January 2015 to December 2020 were retrospectively analyzed, including 28 males and 9 females, with an average age of 47.9±12.0 years (range, 26-72 years). Etiologies included 23 cases of ankylosing spondylitis, 9 cases of infectious arthritis of the hip in youth, and 5 cases of traumatic arthritis after acetabulum or femoral neck fracture. All patients underwent THA with combined anterior and posterior approach. These factors include operation time, blood loss, amount of transfused blood, blood transfusion rate, preoperative and postoperative Harris score, postoperative range of motion of the hip, and perioperative complications, etc. were evaluated. Postoperative radiography of the hip was performed to evaluate acetabular abduction angle, anterior inclination angle, the prosthesis fixation, osteolysis and heterotopic ossification around the hip.Results:A total of 37 patients were enrolled. The mean operative time was 147.6±16.8 min (range, 129-190 min); the mean estimated blood loss (EBL) was 850.0±10.8 ml (range, 600-1,200 ml); the blood transfusion rate was 59% (22/37), and the mean blood transfusion was 420±45.0 ml (range, 0-800 ml). All patients were followed up for 4.2±0.9 years (range, 1.2-7.2 years). The average abductor angle of the acetabular was 43.7°±5.4° (range, 31°-55°), and the average inclination angle was 20.9°±6.7° (range, 10°-35°); the preoperative Harris score was 47.1±9.9 (range, 40-55) and the mean Harris score at the last follow-up was 83.4±12.4 (range, 75-90). The preoperative range of motion of the hip in all directions was 0°. Postoperative hip range of motion was good, with a mean hip flexion of 95.5°±12.2° (range, 80°-110°), mean extension of 10.5°±3.4° (range, -10°-25°), and mean abduction of 38.0°±8.2° (range, 10°-50°). Postoperative complications were minor, including 2 case with poor wound healing, 2 cases with paresthesia or tingling sensation in the anterior or anterolateral thigh, which returned to normal within 3 months after surgery, and no deep infection or dislocation occurred. The acetabular cup was in poor position in 2 cases and the femoral stem was varus in 1 case, but the prosthesis was stable and no treatment was needed. All the acetabular cups and femur stems were confirmed with bone ingrowth on the last follow-up radiographs, and one patient had heterotopic ossification (Brooker grade 1). No osteolysis or wear of the acetabular liner was observed.Conclusion:Combined anterior and posterior approach (Gibson posterolateral approach + modified Hardinge approach) in THA for fusion/ankylosed hip can fully expose the operative field and sufficiently release the soft tissue, and the function of hip recovered well postopratively.

14.
Chinese Journal of Orthopaedics ; (12): 97-103, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993415

RESUMO

Objective:To investigate the effect of 3D-printed customized flanged cup in hip revision with severe acetabular bone defects.Methods:Since February 2017, 10 cases of 3D-printed customized flanged cups were used in hip revision with severe acetabular bone defects, including 2 cases of Paprosky type IIIA and 8 cases of Paprosky type IIIB. There were 5 males and 5 females, mean age 73.6±8.1 yrs (range, 62-87 yrs), 5 left and 5 right cases. The preoperative thin-layer CT scan was preformed to reverse reconstruct digital pelvis. Five cases of one-piece flanged cups and 5 cases of decomposed flanged cups, including 3 cases of composite one-piece cups were designed by computer. The surgery was performed strictly according to the plan.Postoperative follow-up was performed to evaluate the Harris score. Operation time,intraoperative bleeding and other complications such as vascular and nerve injury, postoperative infection, and dislocation were counted. Pelvic X-ray was used to assess the height and horizontal position of the center of rotation and the stability of the prosthesis.Results:The surgical procedure was successful, with an average operative time of 147.9±48.3 min (range, 96-212 min) and an average intraoperative bleeding of 730.4±262.6 ml (range, 500-1 300 ml). The mean time of final follow-up was 40.8±18.7 months (range, 16-70 months) after surgery. At the last follow-up, the average Harris score was 83.80±6.73, with 4 cases excellent, 5 cases good, and 1 case fair. The excellent and good rate was 90%. The last Harris score was significantly higher than that before operation 28.60±8.40 ( t=16.84, P<0.001). The height of affected hip joint rotation center decreased from 46.24±7.74 mm before operation to 15.54±2.54 mm after operation with significant difference ( t=14.61, P<0.001). It was slightly higher than the opposite side (13.81±1.48 mm), which had no significant difference ( t=1.83, P=0.100). The horizontal distance of affected hip joint rotation center increased from 33.79±5.27 mm before operation to 40.53±4.50 mm after operation with significant difference ( t=3.62, P=0.006). It had no significant difference ( t=1.28, P=0.232) compared with the opposite side (38.54±3.46 mm). All incisions were healed in one stage without infection, vascular or nerve injury. During the following-up, all prostheses were in satisfied position without loosening, dislocation or screw breaks. Conclusion:Digitally assisted 3D-printed flanged cups can be used in hip revision with severe acetabular bone defect. It can not only improve hip joint function, but also restore the acetabular rotation center and the prosthesis stability, which can achieve good early and mid-term effect.

15.
Chinese Journal of Orthopaedics ; (12): 62-71, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993411

RESUMO

Objective:To develop a preoperative CT image segmentation algorithm based on artificial intelligence deep learning technology for total hip arthroplasty (THA) revision surgery, and to verify and preliminarily apply it.Methods:A total of 706 revision cases with clear CT data from April 2019 to October 2022 in Chinese PLA General Hospital were retrospectively analyzed, including 520 males, aged 58.45±18.13 years, and 186 females, aged 52.23±16.23 years. All of them were unilateral, and there were 402 hips on the left and 304 hips on the right. The transformer_unet convolutional neural network was constructed and trained using Tensorflow 1.15 to achieve intelligent segmentation of the revision THA CT images. Based on the developed three-dimensional planning system of total hip arthroplasty, an intelligent planning system for revision hip arthroplasty was preliminarily constructed. Dice overlap coefficient (DOC), average surface distance (ASD) and Hausdorff distance (HD) parameters were used to evaluate the segmentation accuracy of transformer_unet, full convolution network (FCN), 2D U-shaped Net and Deeplab v3 +, and segmentation time was used to evaluate the segmentation efficiency of these networks.Results:Compared with the FCN, 2D U-Net, and Deeplab v3+ learning curves, the transformer_unet network could achieve better training effect with less training amount.The DOC of transformer_unet was 95%±4%, the HD was 3.35±1.03 mm, and the ASD was 1.38±0.02 mm; FCN was 94%±4%, 4.83±1.90 mm, 1.42±0.03 mm; 2D U-Net was 93%±5%, 5.27±2.20 mm, and 1.46±0.02 mm, respectively. Deeplab v3+ was 92%±4%, 6.12±1.84 mm, 1.52±0.03 mm, respectively. The transformer_unet coefficients were better than those of the other three convolutional neural networks, and the differences were statistically significant (all P<0.05). The segmentation time of transformer_unet was 0.031±0.001 s, FCN was 0.038±0.002 s, 2D U-Net was 0.042±0.001 s, Deeplab v3+ was 0.048±0.002 s. The segmentation time of transformer_unet was less than that of the other three convolutional neural networks, and the difference was statistically significant ( P<0.05). Based on the results of previous studies, an artificial intelligence assisted preoperative planning system for THA revision surgery was initially constructed. Conclusion:Compared with FCN, 2D U-Net and Deeplab v3+, the transformer_unet convolutional neural network can complete the segmentation of the revision THA CT image more accurately and efficiently, which is expected to provide technical support for preoperative planning and surgical robots.

16.
Chinese Journal of Orthopaedics ; (12): 55-61, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993410

RESUMO

Objective:To investigate the clinical efficacy of preoperative three-dimensional (3D) reconstruction planning in total hip arthroplasty for development dysplasia of the hip secondary to osteoarthritis.Methods:A total of 80 patients with osteoarthritis secondary to Crowe I-III developmental dysplasia of the hip who underwent primary unilateral total hip arthroplasty from October 2019 to March 2021 were retrospectively analyzed, including 18 males and 62 females and the mean age was 55.7±10.4 years (range 41-72 years). Forty patients in the 3D group, the prosthesis type and installation angle were planed on the 3D reconstruction software based on the full-length CT scan data of the lower limbs, and the length difference of the lower limbs and hip offset were calculated. Forty patients in the control group underwent preoperative planning using conventional film measurement, and lower limb length was judged based on the preoperative measurement data and intraoperative comparison of both lower limbs. The difference of postoperative leg length, hip offset, hip function score, operating time, intraoperative blood loss, and incidence of complications were compared between the two groups.Results:All 80 patients completed the surgery successfully and the follow-up time was up to 3 months after operation. The 3D group was better than the control group in operation time (70.9±7.7 min vs. 81.6±13.3 min, t=-4.91, P<0.001), the difference of postoperative lower limb length (2.78±1.31 cm vs. 5.35±2.15 cm, t=-5.74, P<0.001), and hip function score at 1 week after operation (75.67±3.35 vs. 67.35±4.21, t=12.33, P=0.002), with statistically significant differences. In the 3D group, 95% of acetabular prosthesis and 90% of femoral stem components were consistent with the planned model, while the rate were only 75% and 68% in the control group, and the difference was statistically significant (χ 2=7.51, P=0.023; χ 2=14.92, P=0.005). There were no intraoperative complications such as vascular and nerve injury, and no postoperative complications such as dislocation or periprosthetic infection in all 80 patients. Conclusion:3D preoperative planning assisted total hip arthroplasty in the treatment of Crowe I-III developmental dysplasia of the hip secondary to osteoarthritis can improve the accuracy of the operation, and has a good clinical effect on restoring the leg length and hip offset.

17.
Chinese Journal of Orthopaedics ; (12): 9-15, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993404

RESUMO

Objective:To evaluate the early clinical outcomes of 5G remote telesupervised robot assisted total hip arthroplasty in the treatment of Kaschin-Beck disease with hip problems in Tibet through retrospective analysis of the hip surgery cohort.Methods:According to the operation procedure, 55 Kaschin-Beck disease patients (59 hips) undergoing total hip arthroplasty from November 2020 to November 2021 in the Karub District People's Hospital in Qamdo were divided into the conventional THA group (cTHA) and the 5G remote telesupervised robot assisted THA group (rTHA). Two of them underwent cTHA on both hips, while the other two patients underwent cTHA and rTHA separately of each hip, and the rest underwent single hip surgeries. In the cTHA group, there were 30 patients (32 hips), 16 males (17 hips) and 14 females (15 hips), aged 56.56±9.33 years (range, 36-76 years); In the rTHA group, there were 27 patients (27 hips), 10 males and 17 females, aged 55.41±10.90 years (range, 24 to 79 years). Before operation, Harris hip score was recorded and femoral offset (FO) and leg length difference (LLD) were measured via X-ray images. The operation time was collected during the hip surgery and an average network delay of 172.28±36.58 ms and a 1.08% data packet loss ratio is obtained during telesupervision. 24 hours post-operatively, the FO and LLD were both measured via the X-ray images, as well as the inclination and anteversion of the acetabular cup. The Harris scores were collected in the following up. The operation time, FO, LLD, inclination, anteversion and Harris score were compared between the two groups.Results:All cases in both groups were followed up for an average of 9.39±2.43 months (range, 6-19 months). There were no significant differences in pre-operative FO and LLD, preoperative Harris scores or average follow-up time between the two groups. The operation time in rTHA group was 126.41±12.78 min, which is significantly longer than the time 88.81±8.83 min in cTHA group ( t=13.31, P<0.001). After operation, the FO was significantly increased and the LLD was significantly decreased ( P<0.05). The postoperative LLD was 0.63±0.65 cm in the robot group and 1.15±0.71 cm in the conventional group, the difference was statistically significant ( t=2.88, P=0.006). However, there was no significant difference in the FO, inclination and anteversion between the two groups post-operatively ( P>0.05). The Harris scores of both groups were significantly improved compared with that before the operation. Additionally, the Harris score of the two groups was significantly higher than that before surgery, and the postoperative Harris score of the rTHA was 69.00±12.33 higher than that of the cTHA (62.31±11.87), with statistical significance ( t=2.12, P=0.039). The ratio of excellence of Harris score was 19% (5/27) in the rTHA and 9% (3/32) in the cTHA, with no significant difference between groups (χ 2=1.05, P=0.522). Conclusion:Compared to conventional surgery, 5G remote telesupervised robot assisted total hip arthroplasty has more advantages in improving the joint functions in the treatment of hip problems caused by Kashin-beck disease in Tibet Autonomous Region, and facilitates more accurate adjustment of lower limb length difference, even though it consumes more operation time.

18.
Chinese Journal of Orthopaedics ; (12): 5-8, 2023.
Artigo em Chinês | WPRIM | ID: wpr-993403

RESUMO

Many people doubt about its clinical significance, such as prolonged operation duration, longer learning curve , increased medical expenses and robot related complications. On the contrary, with the popularization of technology, the above unfavorable factors also tend to change. Therefore, improving the scientific understanding of robot assisted arthroplasty can promote the development and intersection of related disciplines in this area. The present paper investigated the following advantages of robot in assisting arthroplasty from two aspects, improving the accuracy of prosthesis placement and realizing personalized preoperative planning. Further, the possible shortcomings were discussed in the learning curve, economic factors and related complications. Finally, based on the current clinical situation, the future application direction was pointed out.

19.
Chinese Journal of Orthopaedic Trauma ; (12): 470-477, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992735

RESUMO

Objective:To investigate the early clinical effectiveness of using customized 3D printed acetabular augment to repair large acetabular bone defects in delayed total hip arthroplasty after failed treatment of acetabular fractures.Methods:A retrospective study was conducted to analyze the 6 patients who had undergone 3D printed acetabular augment to reconstruct acetabular bone defects in delayed total hip replacement from July 2021 to January 2023 after failed treatment of acetabular fractures. They were all males, with an age of (51.3±15.0) years. Paprosky classification: 2 cases of type ⅡB, 1 case of type ⅡC, and 3 cases of type ⅢA. Recorded were surgical time, intraoperative bleeding, hospitalization time, and visual analogue scale (VAS), and modified Merle d'Aubigné & Postel score, Harris hip score, and leg length discrepancy at the last follow-up.Results:For the 6 patients, the mean surgical time was (222.5±46.9) min, the mean intraoperative bleeding 1,100 (1,000, 2,625) mL, the mean hospitalization time (9.0±4.5) d, and the mean follow-up time (11.8±7.9) months. At the last follow-up, the VAS [(2.5±1.0) points] significantly decreased compared with the preoperative value [(6.2±0.8) points], the modified Merle d'Aubigné & Postel score [(13.2±2.1) points] and Harris hip score [(67.8±15.3) points] significantly increased compared with the preoperative values [(6.7±0.8) and (34.2±8.4) points], the vertical position of center of rotation [(22.5±5.2) mm] and the horizontal position of center of rotation [(40.7±2.6) mm] were significantly reduced compared with the preoperative values [(38.1±14.2) and (53.1±10.0) mm] ( P<0.05). At the last follow-up, the leg length discrepancy was (6.2±3.6) mm, showing no statistically significant difference from the preoperative value [(18.7±1.7) mm] ( P>0.05). At the last follow-up, no clear line at the cup-bone or augment-bone interface, or no possible prosthetic loosening or displacement was observed on the X-ray films. Conclusion:In delayed total hip arthroplasty after failed treatment of acetabular fractures, the customized 3D printed augment for repair of large bone defects in the acetabulum can reconstruct the normal rotation center of the hip joint, provide reliable stability for the cup prosthesis, and enable patients to obtain significant improvements in hip function.

20.
Chinese Journal of Orthopaedic Trauma ; (12): 254-259, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992705

RESUMO

Objective:To explore the short-term efficacy of fixation with a 3D printed individualized custom-made plate in the treatment of elderly patients with periprosthetic femoral fracture.Methods:Retrospectively analyzed were the 5 elderly patients with periprosthetic femoral fracture who had been treated by fixation with a 3D printed individualized custom-made plate from January 2022 to July 2022 at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital. There were 3 males and 2 females, aged 81, 86, 77, 91 and 87 years, respectively. One left and 4 right limbs were affected. Vancouver classification: type B1 ( n=3), type B2 ( n=1), and type C ( n=1). The time from operation to injury was 5, 6, 10, 5 and 7 days, respectively. Preoperatively, the femur affected, prosthesis and individualized plate with a greater trochanteric hook, loop cable channel and bone-like trabecular microporous structure were custom-made by 3D printing according to 1:1 models. Virtual operations were simulated to formulate surgical protocols. The operation time, length of surgical incision, intraoperative blood loss and transfusion, hospital stay, hip function and complications at the last follow-up were recorded. Results:The 5 patients were followed up for 12, 7, 10, 3 and 6 months, respectively. There were no events of superficial incision or deep prosthesis infection. Respectively, the operation time was 1.8, 1.7, 2.3, 2.0 and 3.3 h; the length of surgical incision 31, 30, 38, 27 and 30 cm; the intraoperative bleeding volume 400, 300, 300, 500 and 600 mL; the length of hospital stay 8, 9, 15, 14 and 11 d. Four patients received intraoperative blood transfusion of 300, 900, 150 and 1, 050 mL, respectively. One patient died of a heart attack 3 months after discharge; another patient developed dyskinesia at the contralateral limb 3 months after discharge due to cerebral infarction and died of recurrent cerebral infarction 7 months after discharge. At the last follow-up, the Harris hip scores of 3 patients were 86, 77 and 69 points, respectively. None of the patients had complications like breakage or loosening of implants.Conclusion:In the treatment of elderly patients with periprosthetic femoral fracture, fixation with a 3D printed individualized custom-made plate may lead to fine limb function and good short-term curative efficacy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA